Pump Neròn HWB 110
MODEL : HWB 110
TYPE : By-pass
FEATURES :
- FEEDING : Self priming (up to 5 mt ) or discharge
- CALIBRATION: Unloader valve or piloted by-pass valve
- SECONDARY FLUID : Fresh water, Glycole, Chemicals
- WATER TEMPERATURE : Cold or hot water with water by-pass to tank (up to 80° C)
- OIL TEMPERATURE : Max 70 °C
- OIL FLOW : Up to 80 l/m with flow limiting valve
- RISK : None, Safety devices adopted both oil and water side
- MATERIAL : Brass, Anodized aluminium, Stainless steel, Special seals
- PISTON MATERIAL : Stainless steel
- DIMENSION : 270x121x125 mm
- WEIGHT : 8.5 kg
- INSTALLATION : Fixing holes on two sides
- INLET AND OUTLET OIL PORT : ½” BSP F
- WATER INLET PORT : ¾” BSP M o ¾” BSP F
- WATER OUTPUT PORT : M22x1,5; 3/8” NPT F; ½” BSP M
BENEFITS :
Technically unbeatable
Full power and trust
Small size
Easy to carry
Simple installation
Connect and use
Installation in any position
Safety devices adopted
Running in any environment conditions
Water cost and volume saving
Low maintenance required
Long life thanks to the oil self-lubrication
Anti explosion, Anti sparks, Anti electric shock
Connection with chemical ejector, soap, solvents or additives
Cost effective
Low noise and low vibrations
PERFORMANCE :
WORKING CONDITIONS |
Oil inlet data | Water output data | |||||
Oil flow into (Q1) | Oil pressure into (P1) | Water flow to the nozzle (Q2) | Water pressure to the nozzle (P2) | Nozzle Ø mm | Water suction | Power KW | |
Min | 18 L/min | 240 bar | 36 L/min | 100 bar | 3,3 | Selfpriming-discharge | 7 |
STD* |
23 L/min | 250 bar | 37 L/min | 110 bar | 3,3 | Selfpriming discharge | 9 |
MAX | 25 L/min | 280 bar | 38 L/min | 120 bar | 3,3 | Selfpriming-discharge | 11 |
*STD Standard calibration done by Neròn.. Different or adjusted calibration done upon customer’s request. The above stated values are subject to variations depending on the oil temperature of the hydraulic system.
ACCESSORIES :
Water filter ¾” BSP FF 80 mesh, hose barb, pressure gauge, flow limiting valve block (on request)